What is InfraStruXure

InfraStruXure Overview

Overview of Types

InfraStruXure Benefits

Total Cost of Ownership Calculator

W e l c o m e   t o  DPSA - National High Power Partner

InfraStruXureTM Overview
 
The InfraStruXureTM Architecture consists of the following standardized pre-assembled components:
= UPS = Row Expander = Rack Enclosure = PDU

You can connect these components in infinite ways to meet your specific needs.Which components you use, and how you connect those components will depend on:

 
  • The Input Power Requirements
     
  • The total power draw of the Area (see Partitioning for information on Areas)
     
  • The number of enclosures you want to deploy
     
  • Availability Tier preference (see Availability Tiers for information)
     
  • The deployment methodology you prefer
Sample Configurations

 
 

1.Type A InfraStruXureTM (Zoned)

 
The UPS and PDU are configured in one rack supporting three additional equipment racks. The UPS can be a Symmetra 2-6kVA or 4-12kVA unit depending on the load density in the supported enclosures.
 

2. Type A InfraStruXureTM (Zoned)

 
The UPS and PDU are configured in one rack supporting three additional equipment racks. The UPS can be a Symmetra 2-6kVA or 4-12kVA unit depending on the load density in the supported enclosures.
 

3. Type B InfraStruXureTM (Zoned)

 
The UPS and PDU are in individual racks supporting 20 racks of equipment in two rows using cabling ladder. The UPS is a Symmetra PX 40kW unit.

 
 

4. Type C InfraStruXureTM (Centralized)"

 
This sample configuration would be used in a large data center with power requirements of roughly 200kW. The UPS is centralized with a PDU supporting two rows of 31 equipment racks for a total of 124 equipment racks.

 

 

For simplicity sake there are basically three types of InfraStruXureTMs you would deploy.
 

For more information on typical InfraStruXureTM configurations see the Overview of Types

 

InfraStruXure provides power protection, environmental control and site monitoring services that are designed to proactively identify and correct problems before downtime occurs. Over the years, InfraStruXure has received more than 150 awards worldwide for reliability and innovation of solutions - more than any other UPS manufacturer.
e X p e r t i s e        e X p e r i e n c e        e X p a n s i o n        e X p e c t
InfraStruXure technicians are fully qualified and trained to install enterprise level solutions.

f
      
InfraStruXure have been installed over 1000 power management solutions to enterprises .
As your business grows your power requirements will grow and a InfraStruXure solution is designed to grow as you require it.
With DPSA you can eXpect the very best service, installation and after sales service

 